WERS rates the complete window or glazed door. It brings the frame, glazing and relevant configuration together. It is a product-rating pathway, distinct from a whole-home NatHERS assessment or a project-specific calculation at actual window dimensions.
What does a WERS rating tell you?
The Window Energy Rating Scheme provides information about the energy performance of windows and glazed doors. The useful result is about the complete product, not just the glass. A glazing value alone leaves out the effect of the frame, edge conditions and the nominated assembly.
- Whole-window U-value (Uw): a measure of heat transfer through the assembly. A lower value indicates less heat transfer under the rating conditions.
- Whole-window solar heat gain coefficient (SHGCw): the fraction of incident solar energy admitted through the complete window. The appropriate target depends on the building design, climate and project requirements; lower is not automatically better for every application.
- Heating and cooling stars: scheme information used to compare energy performance where applicable. Window stars are not the same as a whole-home NatHERS star rating.
Compare like with like. Check that figures refer to the same type of result and an applicable configuration. Centre-of-glass and whole-window values should not be interchanged when specifying a product.
How do manufacturers obtain WERS ratings?
Begin by defining the products and configurations that need rating. The simulation work uses technical information about the system and follows the applicable rating procedures. The WERS pathway also involves the relevant audit and certification arrangements; simulation output alone is not a claim that a product has completed that pathway.
- Define the output. Confirm whether the commercial need is a WERS scheme rating, development comparison or another performance report.
- Scope the product family. Identify opening types, frames, glazing combinations and relevant variants.
- Provide technical inputs. Resolve missing geometry, material or product information before relying on the analysis.
- Complete simulation and the required scheme stages. Agree who is responsible for the simulation, audit, certification and any listing arrangements.
- Use the correct evidence. Match published values and claims to the product and scope they represent.
Current scheme requirements govern the actual process. SIIGMATIC works within the WERS/AFRC pathway; AFRC’s directory identifies CiiLOCK Engineering as a simulation laboratory and AGWA as the WERS audit house. Confirm the current scope and responsibilities when commissioning the work.
What information is needed for a WERS quotation?
Useful inputs include frame drawings or CAD geometry, opening configuration, glazing and spacer details, relevant materials and available air-infiltration or AS 2047 evidence where the pathway requires it. If some information is missing, identify that early so the laboratory can explain what is needed.
The number and complexity of systems and variants, the state of the technical inputs and the requested deliverables affect the scope. Ask for a quotation against a defined product family and confirm current timing. A single generic fee or promised turnaround may not represent the work your range needs.
WERS, NatHERS and custom U-value: which do you need?
| Your question | Relevant pathway |
|---|---|
| How do I rate a window or door product through the Australian scheme? | WERS product rating. |
| What is this system’s thermal performance without WERS submission? | A standalone whole-product performance report, with its status clearly stated. |
| How does the nominated window perform at the actual project size? | Project-specific window U-value and SHGC analysis. |
| How does the home perform as a complete building? | A dwelling energy assessment such as NatHERS through the appropriate assessor. |
WERS uses prescribed rating procedures and dimensions to support consistent product comparison. Project geometry can change frame-to-glass proportions and therefore whole-product performance. An actual-size result can be useful, but it must be accepted through the applicable project or assessment pathway; it is not automatically interchangeable with a scheme rating.
What happens if the glass, frame or system changes?
A different glazing make-up, spacer, frame geometry or configuration can change the result. Check whether the proposed variation is already covered or needs further analysis. Keep the identity of the rated product clear for fabricators, specifiers and customers instead of applying one value indiscriminately across a range.
For development, comparing nominated alternatives can help identify useful changes before the formal rating scope is finalised. Treat an exploratory result as development information until the required verification and scheme stages are complete.
Choose the next step
Explore SIIGMATIC’s WERS rating service, standalone energy-performance reports or custom window U-value analysis. If the route is unclear, send an enquiry describing the product and the result you need.
Further reference
See AGWA’s explanation of WERS and the AFRC industry directory. For the physical-performance side of a window or door, read our AS 2047 testing guide. This overview does not replace the scheme’s current procedures or project-specific advice.
