Security screen and flyscreen assembly testing
Screen manufacturers need to consider the complete assembly, not only the mesh. SIIGMATIC can investigate mechanical performance with the frame, corners, fixings and relevant locking hardware included in the test brief.
Test the assembly,
not only the mesh.
Security screens behave as systems. Mesh performance alone cannot describe the frame, corner, fixing and lock interfaces that determine the complete result.
The required standard and NATA endorsement should be confirmed against the product and market before testing.
What we can
put under test.
Impact / dynamic load
Apply agreed impact or dynamic loading to the complete screen.
Static load
Assess resistance to sustained or prescribed force.
Fixing and frame behaviour
Observe how mesh, frame, corners and fixing interfaces share load.
Lock / latch interaction
Assess locking hardware where it forms part of the security system.
Development comparison
Compare frame, mesh, fastener or corner changes before certification.
Define the complete screen assembly
- Identify the product purpose and any nominated standard or project requirement.
- Provide frame, mesh, corner, fixing and locking details.
- Tell us whether you need development comparison or evidence against a specified method.
A flyscreen is not automatically a security screen or a fall-prevention barrier. These functions require different evidence. Confirm the test method and NATA scope before making a performance claim.